Flintec MCS-64 ModbusOnEthernet Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Flintec MCS-64 ModbusOnEthernet. Flintec MCS-64 ModbusOnEthernet User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 45
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
MCS-64
(Multi Channel System for Process Industry)
Manual MCS-6 with Modbus on Ethernet
Document no. G165-Rev1-GB
Manual MCS-64 Page 1
www.flintec.com
Exc-
Sen-
Sig-
Sig+
Sen+
Exc+
Exc-
Sen-
Sig-
Sig+
Sen+
Exc+
Exc-
Sen-
Sig-
Sig+
Sen+
Exc+
Exc-
Sen-
Sig-
Sig+
Sen+
Exc+
Logic in
Load
Cells
Logic out
C0123CC0123CC0123C C0123C
FLINTEC
www.flintec.com
BC
470uF
+HP
1234
ON DIP
R2
R1
Mt1
Mt27
Mt28
Mt2
J14
T6
T26
Exc-
Sen-
Sig-
Sig+
Sen+
Exc+
Exc-
Sen-
Sig-
Sig+
Sen+
Exc+
Logic in
Load
Cells
Logic out
C0123C C0123C
FLINTEC
www.flintec.com
Y
5
V+
0
5
1
6
9
BC
470uF
+HP
FUSE
5X20
FLINTEC Fl112081 B16
FLINTEC Fl112081 B16
PWR
Com
6
5
4
3
2
1
0
PB Adresse
Profibus Connector
Act
PGM 86.1
PWR
Com
In 0
Out 0
Err
In 1
Out 1
In 2
Out 2
In 3
Out 3
LDM 88.1
PWR
Com
In 0
Out 0
Err
In 1
Out 1
In 2
Out 2
In 3
Out 3
LDM 88.1
PWR
Com
In 0
Out 0
Err
In 1
Out 1
In 2
Out 2
In 3
Out 3
LDM 88.1
PWR
Com
In 0
Out 0
Err
In 1
Out 1
In 2
Out 2
In 3
Out 3
LDM 88.1
PWR
Com
In 0
Out 0
Err
In 1
Out 1
In 2
Out 2
In 3
Out 3
LDM 88.1
Example of MCS-64 with 5 channels and Profibus-Gateway
Vista de página 0
1 2 3 4 5 6 ... 44 45

Resumo do Conteúdo

Página 1 - Manual MCS-64 Page 1

MCS-64(Multi Channel System for Process Industry)Manual MCS-6 with Modbus on EthernetDocument no. G165-Rev1-GBManual MCS-64 Page 1www.flintec.comExc-S

Página 2 - RS485 - Bus

Page 10 Manual MSC-64: Modbus on Ethernet 4.1.2 LDM

Página 3 - LDM 88.1

Manual MCS-64: Modbus on Ethernet Page 112061 Int16 1 R/W Bit commands. Functions regardless of the setting of the LDM selector register. Bit 1:

Página 4 - Contents

Page 12 Manual MSC-64: Modbus on Ethernet Page 0 – Gen

Página 5

Manual MCS-64: Modbus on Ethernet Page 13Register Type Size Access Filling parameter values 2320 Int32 2 R/W Secondary pre-fill level 2322 Int3

Página 6 - 2. SYSTEM DESIGN

Page 14 Manual MSC-64: Modbus on Ethernet Part B 5 C

Página 7 - 2.3.3 The ASCII entry port

Manual MCS-64: Modbus on Ethernet Page 15 5.1 System diagnosis – ID, IV, IS Read these registers to get type, firmware version or device status of Sy

Página 8 - 3 ETHERNET GATEWAY PROFILE

Page 16 Manual MSC-64: Modbus on Ethernet 5.2 Calibra

Página 9 - 4 MODBUS MAPPING

Manual MCS-64: Modbus on Ethernet Page 17 DS Display step size [ Register = 2216, Type = Int32 ] This command allows the output to step up or dow

Página 10 - 4.1.2 LDM Register Map

Page 18 Manual MSC-64: Modbus on Ethernet AZ Absolu

Página 11

Manual MCS-64: Modbus on Ethernet Page 19 FD Factory default settings [ Register = 2266, Type = Int16, Value = 32768 ] This command puts the LDM8

Página 12

Page 2 Manual MCS-64 EthernetLDM 88.1#1Load Cell#1LDM 88.1#2Load Cell#2GatewayFieldbus- Profibus (PGM 68.1)- CANopen (CGM 85.1)- Ethernet (EGM 87.1)RS

Página 13 - Page 6 - Mass Flow Results

Page 20 Manual MSC-64: Modbus on Ethernet 5.3 Motion

Página 14 - 5 COMMANDS

Manual MCS-64: Modbus on Ethernet Page 21 5.4 Filter setting Commands – FM, FL, UR Using the commands FM and FL, a digital filter type and strength c

Página 15

Page 22 Manual MSC-64: Modbus on Ethernet Mode 1 Char

Página 16

Manual MCS-64: Modbus on Ethernet Page 23 5.5 Set Zero/Tare and Reset Zero/Tare Commands – SZ, RZ, ST, RT The following commands allow you to set and

Página 17

Page 24 Manual MSC-64: Modbus on Ethernet ST Set Ta

Página 18

Manual MCS-64: Modbus on Ethernet Page 25 5.6 Output Commands – GG, GN, GT, GS The following commands “Get” the Gross, Net, Tare and ADC (Sample)

Página 19

Page 26 Manual MSC-64: Modbus on Ethernet 5.7 Setpoin

Página 20

Manual MCS-64: Modbus on Ethernet Page 27 Example of positive hysteresis of 100 kg (H1 = +1.00) on a setpoint of 20.00 kg (lines 3 & 4 of table a

Página 21

Page 28 Manual MSC-64: Modbus on Ethernet 5.8 Trigger

Página 22

Manual MCS-64: Modbus on Ethernet Page 29 TL Trigger Level [ Register = 2400, Type = Int32 ] [ Register = 211E, Type = Int32 ] Set the trigger l

Página 23

Manual MCS-64 Ethernet Page 3Linearity < 0.002 % FSExcitation 5 V DC, load cells 100-2 000 Ohm, 6 wire techniqueAnalogue input range ±2.2 mV/V (bip

Página 24

Page 30 Manual MSC-64: Modbus on Ethernet tM(g)TI Ta

Página 25

Manual MCS-64: Modbus on Ethernet Page 31 5.9 Trigger Special Commands– RW, TT, TS, DT, TW, TI, HT Remark: These commands are only available in firm

Página 26

Page 32 Manual MSC-64: Modbus on Ethernet TW Tare Wi

Página 27

Page 34 Manual MSC-64: Modbus on Ethernet 5.10 Save

Página 28

Manual MCS-64: Modbus on Ethernet Page 35 5.11 Filling Commands – PD1 to PD21, DI, SC, AC, GD, DT, SD Remark: These commands are only available in

Página 29

Page 36 Manual MSC-64: Modbus on Ethernet 6 MCS-64 CO

Página 30 - Typical Checkweigher Signal

Manual MCS-64: Modbus on Ethernet Page 37 6.2 Extension Board MB 89.2 for 2 LDM 88.x

Página 31

Page 38 Manual MSC-64: Modbus on Ethernet 6.3 Extensi

Página 32

Manual MCS-64: Modbus on Ethernet Page 39 6.4 Extension Board MB 89.4 for 8 LDM 88.x Exc-Sen-Sig-Sig+Sen+Exc+Exc-Sen-Sig-Sig+Sen+Exc+Exc-Sen-Sig-Sig

Página 33

Page 40 Manual MSC-64: Modbus on Ethernet 6.5 Address

Página 34

Page 4 Manual MSC-64: Modbus on Ethernet Contents Pa

Página 35 - OMPONENTS AND CONFIGURATION

Manual MCS-64: Modbus on Ethernet Page 41 6.6 Address setup guide extension boards for up to 32 channels DIP switch setting see table below MB 89.2

Página 36

Page 42 Manual MSC-64: Modbus on Ethernet 6.7 Example

Página 37 - 4 DI terminal blocks

Manual MCS-64: Modbus on Ethernet Page 43 6.8 Example Liquid Filling Wiring Check ZeroInput 0Input 1pos. PulseLogic inLoadCellsLogic outC 0 1 2 3 C

Página 38 - 8 load cell terminal blocks

Page 44 Manual MSC-64: Modbus on Ethernet 6.9 LDM 88.

Página 39

Manual MCS-64: Modbus on Ethernet Page 45 6.10 Firmware Versions  LDM 88.183 for check weighing and dosing/filling of non fluid products  LDM 88.

Página 40

DDEECCLLAARRAATTIIOONN OOFF CCOONNFFOORRMMIITTYY ß 0 Product: Multi Channel Weighing System Manufacturers designation: MCS-64 Manu

Página 41 - PC6-20kg-C3

Manual MCS-64: Modbus on Ethernet Page 5 6 MCS-64 Components and Configuration...

Página 42 - Service Port

Page 6 Manual MSC-64: Modbus on Ethernet 1. INTRODUCT

Página 43 - Inputs LDM 88.1

Manual MCS-64: Modbus on Ethernet Page 7 2.3 Ethernet Gateway The Ethernet Gateway is using a 10/100baseT on RJ45 connection (IEEE 802.3u standard).

Página 44 - 6.10 Firmware Versions

Page 8 Manual MSC-64: Modbus on Ethernet 3 ETHERNET G

Página 45

Manual MCS-64: Modbus on Ethernet Page 9 4 MODBUS MAPPING The MBAP header “Unit Identifier” field is used to select a module in the backplane. Addre

Comentários a estes Manuais