DAD 141.1 Technical Manual Modbus Communication, Rev. 2.3 - Juni 2014 Page 8
The values of the update rate are 0 to 7 (2 exp 0 = 1, 2 exp 7 = 128).
see also command description: UR Update Rate
This Index enables or disables the zero tracking (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2122.
The values of Zero Tracking function are 0 to 255.
see also command description: ZT Zero Tracking
This Index is used for set the analog output mode.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2128.
The values of the output mode are 0 to 5
see also command description: AM Analog Output Mode
Absolute Gain
Calibration
This Index Reads/Modify the absolute gain point (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2200.
see also command description: AG Absolute Gain
Absolute Zero
Calibration
This Index Reads/Modify the absolute zero point (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2202.
see also command description: AZ Absolute Zero
This Index sets the calibration functions to the enabled state.
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2204.
see also command description: CE Calibrate Enable
This Index sets the calibration gain (span) value (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2206.
see also command description: CG Calibrate Gain
This Index Reads/Modify the maximum allowable output value (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 220C.
see also command description: CM Maximum Output
This Index Reads/Modify the minimum allowable output value (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 220E.
see also command description: CI Minimum Output
This Index sets the calibration zero point (TAC protected).
The 32 bit integer data accessed by writing 2 16-bit registers from index 2212.
see also command description: CZ Calibrate Zero
This Index Reads/Modify the decimal point position (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2214.
see also command description: DP Decimal Point
This Index Reads/Modify the the display step size (TAC protected).
The 32 bit integer data accessed by reading or writing 2 16-bit registers from index 2216.
see also command description: DS Display Step Size
Comentários a estes Manuais