DAD 141.1 Technical Manual, Rev. 2.2 - February 2014
7.9. Menu 7 – Logic Outputs
Logic output setup (Menu 7.0 to 7.2)
Setpoint of weight value for switching (command S’n‘ – n=0)
Permitted values +/- 999999
Logic output "1" switches ON or OFF (command P’n‘ – n=0)
Use the UP/DOWN buttons for "on" / "oFF"
Hysterisis value "0" (± 'n') (command H’n‘ – n=0)
Permitted values +/- 9999
Base for Setpoint "0" (command A’n‘ – n=0)
PEA - Peak value (Maximum)
UALL - Valley value (Minimum)
Test logic output "0" (Use the UP/DOWN buttons)
Open/Close contacts using the keyboard
Logic Output "1" (commands S’n‘, P’n‘, H’n‘, A’n‘ – n=1)
As per section 7.0 - but for logic output "1"
Logic Output "2" (commands S’n‘, P’n‘, H’n‘, A’n‘ – n=2)
As per section 7.0 - but for logic output "2"