DAD 141.1 Technical Manual, Rev. 2.2 - February 2014
3. Introduction and Specifications
The all-in-one Digital Amplifier DAD 141.1 is a universal device for any weighing, filling or loss-in-weight
operation and for force measurements with strain gage sensors. The DAD141 is for DIN (TS35) rail mount.
To grant the quality and allow legal weighing the DAD141.1 is OIML R-76 approved (pending) and meet the
MID E2 requirements to EMC.
The standard device includes all the communication facilities needed for industrial weighing, control and
registration, i.e. analog current or voltage output (0/4…20 mA, 0…5V, 0…10V, -5V…+5V and -10V…+10V),
Ethernet, RS 422/485 and logic I/O’s for direct control of valves or bars etc.
The device can be controlled either by the front keys, via RS 422/485 port or Ethernet port. 2 logic inputs and 3
logic outputs make complex control functions easy. The 3 logic outputs can be controlled external, too.
The device features fullfills multi-drop communications capability and can be programmed via a straightforward
ASCII command set. You can connect up to 32 DAD 141.1onto a single RS485 bus.
Test certificate according OIML R76
EU Type approved for 10000 intervals
±15 mV bipolar (± 3 mV/V @ 5 VDC excitation)
Minimum input sensitivity
0.25 μV/e (legal for trade); 0.05 μV/d (non legal for trade)
Temperature effect on zero
< ±4 ppm/°K (typical < ±2 ppm/°K)
Temperature effect on span
< ±8 ppm/°K (typical < ±4 ppm/°K)
5 V DC, load cell(s) resistance 50 - 2000 ohms; 6 wire technic
Max. 600 values/second, selectable in 8 steps
± 600 000 counts @ ± 3 mV/V input signal
CALIBRATION & WEIGHING FUNCTIONS
Electronical calibration in mV/V (eCal) or with test weight(s)
FIR Filter 2.5 to 19.7 Hz or IIR Filter 0.25 to 18 Hz - adjustable in 8 steps
Zero, gros, tare, net, filter, etc.
None automatic weighing instrument (NAWI) or triggered measurement
Panel buttons or Windows software ‘DOP 4’ or smartphone App ‘AnDOP’
6 digit 7 segments, green LED’s, 5.08mm, 8 status LED green,
spectral filter 565 nm for improved contrast
4 pcs, Ø 3mm robust, for setup / calibration, zero, tare
12 ... 24 V DC ±10 %, < 4 W
-15 °C to +55 °C at maximal 85% rh, non condensing
Plastic housing, for DIN rail mount (TS35) , protection IP40
120 x 105 x 22.5 mm (H x L x W), weight approx. 170 g
EN61326 according to MID E2 for industrial applications (in full
accordance with 2004/22/EC)
2.5g @ operation, 5g @ storage
RS 422/485, 9600 ... 115200 Baud – half/full duplex
ASCII; address range 1 … 31
RJ45, 10/100 Mbit/s, isolated
Ethernet TCP/IP – protocol & port
protocol ASCII, TCP port 23
Modbus TCP – protocol & port
Embedded in TCP/IP packages, protocol binary data, TCP port 502
Setup via serial port or panel buttons – Factory default: 192.168.0.100
0 – 20mA or 4 – 20mA, 500ohm, isolated or
0 – 10V, 0 – 5V, ±5V, ±10V, 10kohm, isolated
2 inputs (10 – 30V, 1 – 3mA), commond ground, isolated
3 outputs (semiconductor relais) 30 V DC/AC, 0.5 A,
common ground, isolated